Thank you for visiting our website. Your personal privacy is absolutely respected and protected by the website. To help you understand how the website collects, uses and protects your personal information, be sure to read the website "Privacy Policy". Thank you!
ACCEPT AND PROCEED

Product

VIBER X3™

VIBER X3™
Product ID: VIBERr X3
Developed for vibration analysts, machine operators, and maintenance technicians. Easy to use, powerful for basic condition monitoring. Helps in maintaining machine reliability and verifying machinery repair. Store and trend condition data with Trend View.
Specifications:
Vibration transducer
Accelerometer
Standard 100 mV/g ± 10%
(Selectable sensitivity in the instrument)
Input amplitude range
Vibration
Max 50 g RMS
With other sensor up to 500 g
Bearing condition
Max 5 gBC
Dynamic range
80 dB (156,08 Hz with auto ranging)
 
 
Frequency range
 
Vibration
2 - 400 Hz
10 - 1000 Hz
6 - 1600 Hz
11 - 3200 Hz
User selectable
Bearing condition
0,5 to 16 kHz
 
Vibration units
g-value, m/s2, mm/s, in/s, µm, mils
User selectable
Amplitude presentation
RMS, Peak, Peak-Peak
User selectable
Analysis
Five highest peaks can be displayed
VMI Trend View Software included for PC
 
Frequency range of peak detec- tion
Frequency range
 
User selectable unit, between Hz and RPM
2 - 400 Hz
6 - 1600 Hz
11 - 2000 Hz
10 - 1000 Hz
Storage capacity
100 measurements can be stored
Three-point balancing
10 balancing results can be stored
Communication interface
USB 2.0
Sound frequency Filter enabled
60 Hz - 10 kHz
+26 dB to -4.1 dB
 
500 Hz - 10 kHz
+26 dB to -4.1 dB
Temperature sensor Range
Built-in infrared sensor
 
0 to 120 °C
 
Accuracy
Vibration
± 3 %
Full scale is 50g for acceleration other units are frequency dependent
Bearing Condition
± 5%
Over 0.03 gBC.
Frequency/RPM
± 0.5 Hz/ ± 30 RPM
 
Temperature
± 1 °C
Emissivity factor must be set in accordance with the target surface.
Battery
Rechargeable Lithium
2300 mA/h, max 60 °C
Capacity of the batteries can vary depending on hardware revision. Max 2300 mAh. (Storage temp. -20 to max 60 °C)
 
Operating time
 
1 week normal use
Operating time depends on backlight, volume level and batteries used. Backlight adds  40mA and the sound volume up to 150mA. Charging time is approx: 6-12 hours.
External charger
5,0 V regulated @ 2000 mA
 
LCD display
B&W 64 x 120 pixels with background light
Operating temp. min 0 °C to max 50 °C, storage temp. max 72 °C
Enclosure protection
IP 65
 
Operating temp. range
0 to 50 °C
The restriction concerns display
Weight
415 gram
Instrument, including battery and transducer
Size (LxWxH)
165mm x 80mm x 50mm
 
OBS. If changing to another accelerometer, the sensitivity (mV/g) have to be changed. This is done in the menu under ”Transducer”.
Features:
  • PC software Trend View™ included
  • Can be used as an Analyzer (fault displaying
    highest peaks from the FFT)
  • Headphones for bearing noice detection
  • Balancing with a new 3-point method
  • Bearing Condition
  • Built-in temperature sensor
  • Selectable alarms
  • Battery charger included
  • Dust and waterproof, for rough use (IP 65)
Order Information:
  • Minimum Order: 1ST
Contact Detail
Contact:Chia-Yuan Chuang
Address:36, Ln 196, Chueh-Ming Rd, Kaohsiung City , Taiwan (R.O.C.)
TEL:+886-7-3966681
FAX:+886-7-3966612
Email: info@leadfar.com.tw
service@leadfar.com.tw
ZIP:807