Specifications:
Vibration transducer
|
Accelerometer
|
Standard 100 mV/g ± 10%
|
(Selectable sensitivity in the instrument)
|
Input amplitude range
|
Vibration
|
Max 50 g RMS
|
With other sensor up to 500 g
|
Bearing condition
|
Max 5 gBC
|
||
Dynamic range
|
80 dB (156,08 Hz with auto ranging)
|
|
|
Frequency range
|
Vibration
|
2 - 400 Hz
10 - 1000 Hz
6 - 1600 Hz
11 - 3200 Hz
|
User selectable
|
Bearing condition
|
0,5 to 16 kHz
|
|
|
Vibration units
|
g-value, m/s2, mm/s, in/s, µm, mils
|
User selectable
|
|
Amplitude presentation
|
RMS, Peak, Peak-Peak
|
User selectable
|
|
Analysis
|
Five highest peaks can be displayed
|
VMI Trend View Software included for PC
|
|
Frequency range of peak detec- tion
|
Frequency range
|
User selectable unit, between Hz and RPM
|
|
2 - 400 Hz
|
|||
6 - 1600 Hz
|
|||
11 - 2000 Hz
|
|||
10 - 1000 Hz
|
|||
Storage capacity
|
100 measurements can be stored
|
||
Three-point balancing
|
10 balancing results can be stored
|
||
Communication interface
|
USB 2.0
|
||
Sound frequency Filter enabled
|
60 Hz - 10 kHz
|
+26 dB to -4.1 dB
|
|
500 Hz - 10 kHz
|
+26 dB to -4.1 dB
|
||
Temperature sensor Range
|
Built-in infrared sensor
|
|
|
0 to 120 °C
|
|||
Accuracy
|
Vibration
|
± 3 %
|
Full scale is 50g for acceleration other units are frequency dependent
|
Bearing Condition
|
± 5%
|
Over 0.03 gBC.
|
|
Frequency/RPM
|
± 0.5 Hz/ ± 30 RPM
|
|
|
Temperature
|
± 1 °C
|
Emissivity factor must be set in accordance with the target surface.
|
|
Battery
|
Rechargeable Lithium
|
2300 mA/h, max 60 °C
|
Capacity of the batteries can vary depending on hardware revision. Max 2300 mAh. (Storage temp. -20 to max 60 °C)
|
Operating time
|
1 week normal use
|
Operating time depends on backlight, volume level and batteries used. Backlight adds 40mA and the sound volume up to 150mA. Charging time is approx: 6-12 hours.
|
|
External charger
|
5,0 V regulated @ 2000 mA
|
|
|
LCD display
|
B&W 64 x 120 pixels with background light
|
Operating temp. min 0 °C to max 50 °C, storage temp. max 72 °C
|
|
Enclosure protection
|
IP 65
|
|
|
Operating temp. range
|
0 to 50 °C
|
The restriction concerns display
|
|
Weight
|
415 gram
|
Instrument, including battery and transducer
|
|
Size (LxWxH)
|
165mm x 80mm x 50mm
|
|
|
OBS. If changing to another accelerometer, the sensitivity (mV/g) have to be changed. This is done in the menu under ”Transducer”.
|
Features:
- PC software Trend View™ included
- Can be used as an Analyzer (fault displaying
highest peaks from the FFT) - Headphones for bearing noice detection
- Balancing with a new 3-point method
- Bearing Condition
- Built-in temperature sensor
- Selectable alarms
- Battery charger included
- Dust and waterproof, for rough use (IP 65)