VIBER X5 MK III™ is capable of measuring, processing, displaying and storing a wide range of measurement parameters. You can collect various types of field data; examples are vibration information,bearing analyze, temperature, speed and other process variables that enables you to expand its functionality by adding new measurements to improve your analysis capabilities. You may also use the VIBER X5 MK III™ for 1 or 2 plane balancing.
Specifications:
Digital
|
DSP Processor
|
Texas TMS320C6713B
|
|
Memory
|
Storage: 4 GB micro SD card 128 MB RAM
2*16 MB fast flash memory
|
Minimum spec. Actual spec. is depending on hardware revision
|
|
ADC
|
16 bit, max 192 KSPS simultaneous sampling
|
|
|
Display
|
Size & Resolution
|
5” Amorphous TFT LCD 480 x 272 pixels
|
|
Colours
|
65536
|
|
|
Signals in/out
|
AC inputs
|
All standard ICP accelerometers (4mA/24V), velocimeters or general purpose AC transducers in range 0-30 V RMS
|
VMI default transducers are automatically recognized
|
DC input
|
0 to 5 V
|
|
|
External reference
|
0,8 to 24 V
|
|
|
Built-in trans- ducers
|
Thermal camera
|
Resolotion 80x60, Temp range -20° to +250°C, Accuracy 2% or ± 2°C, Fild of view 51°H x 63°V, Minimum focus ditance 0.5m, Color plate Iron & Gray, Frame rate 9Hz.
|
Infrared
|
Tachometer
|
30 - 60000 RPM
|
Retro-Reflective
|
|
Measurements
|
Processing
|
Direct, single or double integrated or derivated (configured in software upon used transducer and user request). Up to three channels simultaneous sampling
|
|
Frequency range
|
0.5 to 32000 Hz
|
Depending on transducer
|
|
Amplitude range
|
0 to 80 g
|
Depending on transducer
|
|
Accuracy
|
0.01 g ± 1 % for non integrated
0.1 mm/s ± 2 % for single integrated 2 µm ± 3 % for double integrated
|
|
|
FFT lines
|
25600
|
|
|
Sampling rate
|
Up to 131072 Hz depending of selected frequency range
|
Three channels simultaneous sampling
|
|
Windowing
|
Selectable: Hanning, Hamming, Blackmann, Kaiser-Bessel
|
|
|
Power
|
Accumulators
|
6.2 Ah Li-ion fule gauge smart battery pack
|
|
Autonomy
|
12 hours typical use
|
|
|
Charging
|
4 hours typical charge time
|
|
|
Temperature
|
Operating Storage
|
-20 °C to +70 °C (-4 °F to 158 °F)
-30 °C to +80 °C (-22 °F to 176 °F)
|
|
Features: